BlueFlow hot runner nozzle type 5SEF /-DEF

Order code

Example: BlueFlow® Single nozzle 5SEF 50/R40

5Material tube Ø 4,8 mm
SEFOpen single nozzle with tip and thickfilm heater
50Length (L) 50 mm
R40Radius 40 mm


Please indicate material type, article, part weight, kind of gating, gate-Ø and machine nozzle radius/ angle in your order

Notes

In all cases, the _EF nozzle type can be used only with a heated machine nozzle.
In single nozzle systems the size of the locating ring and screws has to compensate for the developing drive power.
The pitch circle of the screws must be as small as possible.
The nozzles must be installed with an initial tension of 0.02 mm to 0.05 mm.

 

51 Only for the adapter without radius
53 Only for different radius/angle
120 Recess for the power and thermo connection
R/W The construction of the machine nozzle determines which type of connecting piece should be used (straight, radius R/ angle W).
135 Recess for the power and thermo connection


The BlueFlow ® hot runner nozzle type SEF/ DEF is not for sale or use in the U.S. and Canada!

Download

Data sheets - BlueFlow® hot runner nozzle type 5SEF /-DEF

Here is where you will find relevant information about the BlueFlow® hot runner nozzle type 5SEF/-DEF as a PDF file.



Modular structure Download
System structure Download
Technical data Download
Gate bushing Download